Installation Method: |
Horizontal |
---|---|
Operation Type: |
Automatic |
Medium Material: | Chemical Synthetic Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TYPE PPCA128 Double Series | PPCA128-2X6 | PPCA128-2X7 | PPCA128-2X8 | PPCA128-2X9 | PPCA128-2X10 | PPCA128-2X11 | PPCA128-2X12 | PPCA128-2X13 | PPCA128-2X14 | ||||||||||
air volume(m 3 /h) | 134600 | 15700 | 179400 | 201900 | 224300 | 147600 | 269100 | 291600 | 314000 | ||||||||||
filter air speed(m/min) | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | ||||||||||
total filter area(m 2 ) | 1869 | 2128 | 2492 | 2804 | 3115 | 3427 | 3738 | 4050 | 4361 | ||||||||||
net filter area(m 2 ) | 1713 | 2025 | 2336 | 2648 | 2959 | 3271 | 3582 | 3894 | 4205 | ||||||||||
No. of room | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | ||||||||||
total No. of bag | 1536 | 1792 | 2084 | 2304 | 2560 | 2816 | 3072 | 3328 | 3584 | ||||||||||
pressure(Pa) | 1470-1770 | ||||||||||||||||||
dust concentration at inlet (g/m3) |
<1000 | ||||||||||||||||||
dust concentration at outlet (g/m3)) |
30 | ||||||||||||||||||
dust collector gas under negative pressure (Pa) |
6860 | ||||||||||||||||||
pressure air for cleaning | pressure (Pa) |
(5-7)X10 5 | |||||||||||||||||
gas consumption (m3/min) |
7 | 8.3 | 9.5 | 10.7 | 12 | 13.1 | 14.3 | 15.5 | 16.7 | ||||||||||
pulse valve (with solenoid valve) |
quantity (set) |
24 | 28 | 32 | 36 | 40 | 44 | 48 | 52 | 56 | |||||||||
size (inch) |
2-1/2″ | ||||||||||||||||||
poppet valve (with cylinder) |
quantity (set) |
12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | |||||||||
size (inch) |
poppet valve board diameter:φ725,cylinder diameter:φ100. | ||||||||||||||||||
rotary valve and specification(mm) |
|
||||||||||||||||||
chute specification:300mm,chute air volume:2.0m 3 /m 2 ( breathable layer),wind pressure:6860Pa The fan types and pipeline collocation are in charge of the chooser. If dust concentration at inlet is larger than 700g/m 3 ,you should choose the dust collector with screw conveyor. |
|||||||||||||||||||
dust cleaning program controller | voltage input and output both are 220V,controller is matching supplied by the manufacturing factory,details please refer to controller instructions. | ||||||||||||||||||
filter bag specifiation and material | diameterXlength:φ130X3060mm,polyester needle felt weight:450g/m 2 ,using temperature:120° (PPCS(A)128 type,filter bag specification can also be φ130X2450mm) |
||||||||||||||||||
remarks: 1 The net filter area in the form means in a certain room dust cleaning filter area. 2 Gas consumption in the form means factory centralized gas supply ,for example, when set up an alone air compressor, gas consumption in the form need to be multiplied 1.3. 3\ The air volume in the form got when the gross filter wind speed is 1.2m/min, which only be true when the dust concentration around the user is smaller than 30g/m3 and the net filter wind speed is not sure. You can choose directly according to the air volume marked in the form. In genaral, you ought to follow the steps in the illustrated book to choose the types. |